Inflow-exhaust ventilation units with heat recovery (plate heat exchanger) and built-in automation, up to 1400 m3 per hour.
Ventilation unit EZ FPV – floor installation, vertical
Supply air flow | 500 m3/h | Нeat exchanger | Plate |
Extract air flow | 500 m3/h | Nominal power input | 2.5 kW |
Air velocity in the supply section | 0.99 m/s | Duct connection | Ø 160 mm |
Air velocity in the extract section | 0.99 m/s | Total weight + damper, electric heater | 84 + 1 +1 kg |
Supply external static pressure | 150 Pa | Width | 498 mm |
Extract external static pressure | 150 Pa | Length | 1070 mm |
Design winter temperature | -22 °C | Height + legs | 832 + 150 mm |
Heat recovery efficiency | 81.02 % |
Supply air flow | 750 m3/h | Нeat exchanger | Plate |
Extract air flow | 750 m3/h | Nominal power input | 4.7 kW |
Air velocity in the supply section | 1.16 m/s | Duct connection | Ø 250 mm |
Air velocity in the extract section | 1.16 m/s | Total weight + damper, electric heater | 94 + 3 kg |
Supply external static pressure | 150 Pa | Width | 598 mm |
Extract external static pressure | 150 Pa | Length | 1250 mm |
Design winter temperature | -22 °C | Height + legs | 950 + 150 mm |
Heat recovery efficiency | 81.34 % |
Supply air flow | 1000 m3/h | Нeat exchanger | Plate |
Extract air flow | 1000 m3/h | Nominal power input | 5.6 kW |
Air velocity in the supply section | 1.54 m/s | Duct connection | Ø 250 mm |
Air velocity in the extract section | 1.54 m/s | Total weight + damper, electric heater | 104 + 2 kg |
Supply external static pressure | 150 Pa | Width | 598 mm |
Extract external static pressure | 150 Pa | Length | 1250 mm |
Design winter temperature | -22 °C | Height + legs | 950 + 150 mm |
Heat recovery efficiency | 78.9 % |
Supply air flow | 1500 m3/h | Нeat exchanger | Plate |
Extract air flow | 1500 m3/h | Nominal power input | 9.2 kW |
Air velocity in the supply section | 2.08 m/s | Duct connection | Ø 500×300 mm |
Air velocity in the extract section | 2.08 m/s | Total weight + damper, electric heater | 204 + 12 +10 kg |
Supply external static pressure | 150 Pa | Width | 706 mm |
Extract external static pressure | 150 Pa | Length | 1660 mm |
Design winter temperature | -22 °C | Height + legs | 1250 + 150 mm |
Heat recovery efficiency | 75.22 % |
The type of installation is an energy-efficient inflow-exhaust system using a plate-type recuperator.
The productivity of this installation reaches up to 1400 m³/h.
It is designed to comprehensively address the challenges of local ventilation in small and medium residential and administrative spaces.
All units come with built-in automation. Controllers and all control elements are configured and ready for operation:
Monitoring equipment operation parameters, automatic restart.
Smooth regulation, maintaining the temperature of the incoming air.
Receiving signals about filter contamination, emergency alarms.
Control of dampers with servo drives and other available options.
Detailed Equipment Specifications PDF File: