Supply and exhaust ventilation units with heat recovery (plate heat exchanger) and built-in automation, up to 1400 m3 per hour.
Ventilation unit EZ FPH – floor installation, horizontal
Supply air flow | 500 m3/h | Нeat exchanger | Plate |
Extract air flow | 500 m3/h | Nominal power input | 2.7 kW |
Air velocity in the supply section | 0.69 m/s | Duct connection | Ø 160 mm |
Air velocity in the extract section | 0.69 m/s | Total weight + damper, electric heater | 91 + 1 +2 kg |
Supply external static pressure | 150 Pa | Width | 498 mm |
Extract external static pressure | 150 Pa | Length | 1170 mm |
Design winter temperature | -22 °C | Height + legs | 802 + 150 mm |
Heat recovery efficiency | 81.02 % |
Supply air flow | 750 m3/h | Нeat exchanger | Plate |
Extract air flow | 750 m3/h | Nominal power input | 4.7 kW |
Air velocity in the supply section | 0.61 m/s | Duct connection | Ø 315 mm |
Air velocity in the extract section | 0.61 m/s | Total weight + damper, electric heater | 109 + 1 +3 kg |
Supply external static pressure | 150 Pa | Width | 598 mm |
Extract external static pressure | 150 Pa | Length | 1250 mm |
Design winter temperature | -22 °C | Height + legs | 942 + 150 mm |
Heat recovery efficiency | 81.34 % |
Supply air flow | 1000 m3/h | Нeat exchanger | Plate |
Extract air flow | 1000 m3/h | Nominal power input | 5.6 kW |
Air velocity in the supply section | 0.82 m/s | Duct connection | Ø 315 mm |
Air velocity in the extract section | 0.82 m/s | Total weight + damper, electric heater | 116 + 1 +2 kg |
Supply external static pressure | 150 Pa | Width | 598 mm |
Extract external static pressure | 150 Pa | Length | 1250 mm |
Design winter temperature | -22 °C | Height + legs | 942 + 150 mm |
Heat recovery efficiency | 78.9 % |
Supply air flow | 1500 m3/h | Нeat exchanger | Plate |
Extract air flow | 1500 m3/h | Nominal power input | 9.2 kW |
Air velocity in the supply section | 2.08 m/s | Duct connection | Ø 500×300 mm |
Air velocity in the extract section | 2.08 m/s | Total weight + damper, electric heater | 211 + 12 +10 kg |
Supply external static pressure | 150 Pa | Width | 706 mm |
Extract external static pressure | 150 Pa | Length | 1560 mm |
Design winter temperature | -22 °C | Height + legs | 1100 + 150 mm |
Heat recovery efficiency | 75.22 % |
The type of installation is an energy-efficient inflow-exhaust system using a plate-type recuperator.
The productivity of this installation reaches up to 1400 m³/h.
It is designed to comprehensively address the challenges of local ventilation in small and medium residential and administrative spaces.
All units come with built-in automation. Controllers and all control elements are configured and ready for operation:
- Monitoring equipment operation parameters, automatic restart.
- Smooth regulation, maintaining the temperature of the incoming air.
- Receiving signals about filter contamination, emergency alarms.
- Control of dampers with servo drives and other available options.